Clara® Inhibitor-Tolerant Probe Mix

Clara® Inhibitor-Tolerant Probe Mix is a broad-spectrum inhibitor-tolerant 4x mix for probe-based qPCR.

Get cutting edge DNA detection even in the presence of PCR inhibitors with Clara® Inhibitor-Tolerant Probe Mix. This broad spectrum, inhibitor-tolerant qPCR mix is expertly designed to overcome challenging laboratory, environmental, and clinical sample inhibitors, ensuring reliable results and streamlined workflows for DNA detection. For end-users wishing to amplify RNA we recommend Clara® Inhibitor-Tolerant Probe 1-Step Mix.

Features:

  • Broad spectrum inhibitor tolerance
  • Concentrated 4x mix format, ideal for high-throughput, highly multiplexed assays
  • Superior detection of DNA targets
  • Reliable quantification of low template amounts
  • Antibody-mediated hot start technology
  • Compatible with all real-time PCR platforms – standard and fast cycling conditions
  • Standard and ultra-fast cycling (down to 3 min RT reaction and 1 s denaturation, 3 s annealing/extension for PCR)
CAT No.
Product
Size
Price
QTY
PB20.71-01
Clara® Inhibitor-Tolerant Probe Mix Lo-ROX
200 x 20 μL Reactions
$267.00
PB20.71-03
Clara® Inhibitor-Tolerant Probe Mix Lo-ROX
600 x 20 μL Reactions
$761.00
PB20.71-05
Clara® Inhibitor-Tolerant Probe Mix Lo-ROX
1000 x 20 μL Reactions (5 x 1 mL)
$1,260.00
PB20.71-50
Clara® Inhibitor-Tolerant Probe Mix Lo-ROX
10 000 x 20 μL Reactions (1 x 50 mL)
PB20.72-01
Clara® Inhibitor-Tolerant Probe Mix Hi-ROX
200 x 20 μL Reactions
$267.00
PB20.72-03
Clara® Inhibitor-Tolerant Probe Mix Hi-ROX
600 x 20 μL Reactions
$761.00
PB20.72-05
Clara® Inhibitor-Tolerant Probe Mix Hi-ROX
1000 x 20 μL Reactions (5 x 1 mL)
$1,260.00
PB20.72-50
Clara® Inhibitor-Tolerant Probe Mix Hi-ROX
10 000 x 20 μL Reactions (1 x 50 mL)
PB20.73-01
Clara® Inhibitor-Tolerant Probe Mix No-ROX
200 x 20 μL Reactions
$267.00
PB20.73-03
Clara® Inhibitor-Tolerant Probe Mix No-ROX
600 x 20 μL Reactions
$761.00
PB20.73-05
Clara® Inhibitor-Tolerant Probe Mix No-ROX
1000 x 20 μL Reactions (5 x 1 mL)
$1,260.00
PB20.73-50
Clara® Inhibitor-Tolerant Probe Mix No-ROX
10 000 x 20 μL Reactions (1 x 50 mL)
PB20.74-01
Clara® Inhibitor-Tolerant Probe 1-Step Mix Separate-ROX
200 x 20 μL Reactions
$267.00
PB20.74-03
Clara® Inhibitor-Tolerant Probe 1-Step Mix Separate-ROX
600 x 20 μL Reactions
$761.00
PB20.74-05
Clara® Inhibitor-Tolerant Probe 1-Step Mix Separate-ROX
1000 x 20 μL Reactions (5 x 1 mL)
$1,260.00

To view your price please login or contact us

More Information

What is the Clara® Inhibitor-Tolerant Probe Mix?

PCR and qPCR can be inhibited by a wide variety of chemical compounds, negatively affecting qPCR workflows and diagnostic processes. Clara® Inhibitor-Tolerant Probe Mix is a 4x reaction-ready mix that includes a DNA polymerase, buffering agents, magnesium, dNTPs, and other necessary components for successful probe-based qPCR, all in a single-tube format. The end user can combine this mix with primers, probes, and templates for single- or multiplex detection. This mix is universally compatible with all probe chemistries, including TaqMan, Scorpions, and molecular beacons, and is maximally compatible with all commercial real-time PCR instruments. Clara® Inhibitor-Tolerant Probe Mix is designed for use in in vitro diagnostic (IVD) kit development and various research applications requiring efficient, reliable qPCR reactions.

What type of templates is this mix suitable for?

The Clara® Inhibitor-Tolerant Probe Mix is suitable for the amplification of DNA templates.

Types of inhibitors Clara® Inhibitor-Tolerant Probe Mix tolerates.

The Clara® Inhibitor-Tolerant Probe Mix has been tested against, and is tolerant to, a broad range of common PCR inhibitors, including standard laboratory chemicals (SDS, guanidine, and ethanol) and biological sample inhibitors, such as those found in blood samples (hemin, hematin, haemoglobin, heparin, IgG immunoglobulins, lactoferrin, sodium citrate), saliva, urine (urea), plant, and environmental samples (humic acid, catechin, quercetin, tannic acid, cellulose, and chlorophyll). The mix has been extensively validated against crude (or diluted) saliva and blood, along with multiple other pure chemical inhibitors.

Applications

  • Species abundance quantification
  • Genotyping
  • Allelic discrimination
  • In vitro diagnostic kit development
  • Single & multiplex DNA detection
  • Crude saliva qPCRs

Specifications

Clara® Inhibitor-Tolerant Probe Mix Lo-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

10,000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix Lo-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Hi-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

10,000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix Hi-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix No-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

10,000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix No-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Separate-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix No-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

50 μΜ ROX Additive

1 x 200 μL

1 x 200 μL

1 x 200 μL

Clara® Inhibitor-Tolerant Probe Mix Lo-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix Lo-ROX



200 Reactions

1 x 1 mL

600 Reactions

3 x 1 mL

1000 Reactions

5 x 1 mL

10,000 Reactions

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Hi-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix Hi-ROX



200 Reactions

1 x 1 mL

600 Reactions

3 x 1 mL

1000 Reactions

5 x 1 mL

10,000 Reactions

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix No-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix No-ROX



200 Reactions

1 x 1 mL

600 Reactions

3 x 1 mL

1000 Reactions

5 x 1 mL

10,000 Reactions

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Separate-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix No-ROX

50 μΜ ROX Additive



200 Reactions

1 x 1 mL

1 x 200 μL

600 Reactions

3 x 1 mL

1 x 200 μL

1000 Reactions

5 x 1 mL

1 x 200 μL

Reaction Volume

Storage

20 μL

On arrival, products should be stored between -30 °C and -20 °C. If stored correctly the kit will retain full activity until the indicated expiry date.

Reaction Volume

20 μL

Storage

On arrival, products should be stored between -30 °C and -20 °C. If stored correctly the kit will retain full activity until the indicated expiry date.

Instrument Compatibility

This product is compatible with all standard and fast cycling qPCR instruments. Use our qPCR Selection Tool to find out which ROX variant is compatible with your instrument.

FAQs

Can I conduct fast cycling with this mix?

Reliable amplification for various targets has been achieved using 40 cycles with 1 s denaturation and 3 s annealing and extension (2-step cycling). Successful amplification under these conditions requires reasonably short amplicons and should be tested on case-by-case basis for all new targets added to an experiment.

Can I use crude plant extracts with this mix?

Results will differ depending on the plant species and tissue type. Our inhibitor-tolerant chemistry shows moderate resistance to chlorophyll and polyphenols, such as catechin and quercetin, but low resistance to tannic acid, cellulose and pectin. Thus, testing the mix on the desired sample types is recommend. All plant tissues will require mechanical lysis in an appropriate extraction buffer to achieve disruption of cell walls and membranes, prior to use with inhibitor-tolerant mixes. We recommend testing a small number of reactions on the target sample type. Please reach out to our team [email protected] to request a product sample, or if you need assistance in planning such test reactions.

Do I need to pre-treat saliva samples before using them with this mix?

Saliva samples do not require pre-treatment. However, dilution in appropriate sample transport medium is recommended. We highly recommend the use of UTM which don’t contain guanidinum chloride.

How much crude blood can I add per reaction?

We have successfully carried out multiplex reactions on up to 5 μL of blood sample (1.25 μL of crude blood diluted 1:4 in a NaCl/EDTA solution) per 20 μL reaction. This does lead to a reduction in overall fluorescence but does not inhibit qPCR reactions themselves, nor does it limit the sensitivity of the mix.

How much crude saliva can I add per reaction?

We have successfully tested up to 10% crude saliva per reaction, with best, most-consistent results when using 2.5% saliva

 

Is it normal to see some delay in Cq in the presence of crude samples?

Yes. While the mix is inhibitor-tolerant, it is not completely resistant to the presence of inhibitors. Different inhibitors and higher concentrations can still inhibit qPCR reactions. Given the sensitivity of the mix, if a significant delay is observed, we recommend diluting the sample before using in qPCR reactions.

Is it normally to see different levels of inhibition with different crude samples?

Yes, this is expected. Crude biological samples, particularly saliva, contain different levels of PCR inhibitors. We have observed a range of 0.5-3.5 cycles delay in amplification of the same target with different saliva samples. The same crude biological sample may also show different levels of inhibition over time.

What inhibitors does this mix tolerate?

All our inhibitor-tolerant mixes have been tested on and tolerate crude saliva and crude blood. Additionally, they have been extensively tested in the presence of multiple PCR inhibitors found in clinical, plant, environmental, and laboratory chemicals . These include: hemin, haemoglobin, heparin, lactoferrin, IgG immunoglobulins, guanidine, SDS, ethanol, urea, sodium citrate, humic acid, cellulose, pectin, quercetin, catechin, tannic acid, and chlorophyll B. The extent of tolerance varies by compound. The mixes may also be tolerant to other compounds, not listed, or not yet tested.

 

 

More Information

What is the Clara® Inhibitor-Tolerant Probe Mix?

PCR and qPCR can be inhibited by a wide variety of chemical compounds, negatively affecting qPCR workflows and diagnostic processes. Clara® Inhibitor-Tolerant Probe Mix is a 4x reaction-ready mix that includes a DNA polymerase, buffering agents, magnesium, dNTPs, and other necessary components for successful probe-based qPCR, all in a single-tube format. The end user can combine this mix with primers, probes, and templates for single- or multiplex detection. This mix is universally compatible with all probe chemistries, including TaqMan, Scorpions, and molecular beacons, and is maximally compatible with all commercial real-time PCR instruments. Clara® Inhibitor-Tolerant Probe Mix is designed for use in in vitro diagnostic (IVD) kit development and various research applications requiring efficient, reliable qPCR reactions.

What type of templates is this mix suitable for?

The Clara® Inhibitor-Tolerant Probe Mix is suitable for the amplification of DNA templates.

Types of inhibitors Clara® Inhibitor-Tolerant Probe Mix tolerates.

The Clara® Inhibitor-Tolerant Probe Mix has been tested against, and is tolerant to, a broad range of common PCR inhibitors, including standard laboratory chemicals (SDS, guanidine, and ethanol) and biological sample inhibitors, such as those found in blood samples (hemin, hematin, haemoglobin, heparin, IgG immunoglobulins, lactoferrin, sodium citrate), saliva, urine (urea), plant, and environmental samples (humic acid, catechin, quercetin, tannic acid, cellulose, and chlorophyll). The mix has been extensively validated against crude (or diluted) saliva and blood, along with multiple other pure chemical inhibitors.

Applications

  • Species abundance quantification
  • Genotyping
  • Allelic discrimination
  • In vitro diagnostic kit development
  • Single & multiplex DNA detection
  • Crude saliva qPCRs

Specifications

Clara® Inhibitor-Tolerant Probe Mix Lo-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

10,000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix Lo-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Hi-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

10,000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix Hi-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix No-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

10,000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix No-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Separate-ROX

Component

200 Reactions

600 Reactions

1000 Reactions

4x Clara Inhibitor-Tolerant Probe Mix No-ROX

1 x 1 mL

3 x 1 mL

5 x 1 mL

50 μΜ ROX Additive

1 x 200 μL

1 x 200 μL

1 x 200 μL

Clara® Inhibitor-Tolerant Probe Mix Lo-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix Lo-ROX



200 Reactions

1 x 1 mL

600 Reactions

3 x 1 mL

1000 Reactions

5 x 1 mL

10,000 Reactions

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Hi-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix Hi-ROX



200 Reactions

1 x 1 mL

600 Reactions

3 x 1 mL

1000 Reactions

5 x 1 mL

10,000 Reactions

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix No-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix No-ROX



200 Reactions

1 x 1 mL

600 Reactions

3 x 1 mL

1000 Reactions

5 x 1 mL

10,000 Reactions

1 x 50 mL

Clara® Inhibitor-Tolerant Probe Mix Separate-ROX

Component

4x Clara Inhibitor-Tolerant Probe Mix No-ROX

50 μΜ ROX Additive



200 Reactions

1 x 1 mL

1 x 200 μL

600 Reactions

3 x 1 mL

1 x 200 μL

1000 Reactions

5 x 1 mL

1 x 200 μL

Reaction Volume

Storage

20 μL

On arrival, products should be stored between -30 °C and -20 °C. If stored correctly the kit will retain full activity until the indicated expiry date.

Reaction Volume

20 μL

Storage

On arrival, products should be stored between -30 °C and -20 °C. If stored correctly the kit will retain full activity until the indicated expiry date.

Instrument Compatibility

This product is compatible with all standard and fast cycling qPCR instruments. Use our qPCR Selection Tool to find out which ROX variant is compatible with your instrument.

FAQs

Can I conduct fast cycling with this mix?

Reliable amplification for various targets has been achieved using 40 cycles with 1 s denaturation and 3 s annealing and extension (2-step cycling). Successful amplification under these conditions requires reasonably short amplicons and should be tested on case-by-case basis for all new targets added to an experiment.

Can I use crude plant extracts with this mix?

Results will differ depending on the plant species and tissue type. Our inhibitor-tolerant chemistry shows moderate resistance to chlorophyll and polyphenols, such as catechin and quercetin, but low resistance to tannic acid, cellulose and pectin. Thus, testing the mix on the desired sample types is recommend. All plant tissues will require mechanical lysis in an appropriate extraction buffer to achieve disruption of cell walls and membranes, prior to use with inhibitor-tolerant mixes. We recommend testing a small number of reactions on the target sample type. Please reach out to our team [email protected] to request a product sample, or if you need assistance in planning such test reactions.

Do I need to pre-treat saliva samples before using them with this mix?

Saliva samples do not require pre-treatment. However, dilution in appropriate sample transport medium is recommended. We highly recommend the use of UTM which don’t contain guanidinum chloride.

How much crude blood can I add per reaction?

We have successfully carried out multiplex reactions on up to 5 μL of blood sample (1.25 μL of crude blood diluted 1:4 in a NaCl/EDTA solution) per 20 μL reaction. This does lead to a reduction in overall fluorescence but does not inhibit qPCR reactions themselves, nor does it limit the sensitivity of the mix.

How much crude saliva can I add per reaction?

We have successfully tested up to 10% crude saliva per reaction, with best, most-consistent results when using 2.5% saliva

 

Is it normal to see some delay in Cq in the presence of crude samples?

Yes. While the mix is inhibitor-tolerant, it is not completely resistant to the presence of inhibitors. Different inhibitors and higher concentrations can still inhibit qPCR reactions. Given the sensitivity of the mix, if a significant delay is observed, we recommend diluting the sample before using in qPCR reactions.

Is it normally to see different levels of inhibition with different crude samples?

Yes, this is expected. Crude biological samples, particularly saliva, contain different levels of PCR inhibitors. We have observed a range of 0.5-3.5 cycles delay in amplification of the same target with different saliva samples. The same crude biological sample may also show different levels of inhibition over time.

What inhibitors does this mix tolerate?

All our inhibitor-tolerant mixes have been tested on and tolerate crude saliva and crude blood. Additionally, they have been extensively tested in the presence of multiple PCR inhibitors found in clinical, plant, environmental, and laboratory chemicals . These include: hemin, haemoglobin, heparin, lactoferrin, IgG immunoglobulins, guanidine, SDS, ethanol, urea, sodium citrate, humic acid, cellulose, pectin, quercetin, catechin, tannic acid, and chlorophyll B. The extent of tolerance varies by compound. The mixes may also be tolerant to other compounds, not listed, or not yet tested.